Kolpak KFX8-1006-CR

Brand
Kolpak
Certifications
NSF
Shipping
Standard Shipping
Nominal Depth
6 Feet
Nominal Width
10 Feet
Series
Kold-Front
Type
Kold-Front
Category
Walk In Cooler,Modular
Compressor Location
Remote
With Floor
Floorless
Usage
Indoor
Voltage
208/230 Volts
Width (in)
116
Height (in)
102
Depth (in)
70
Weight
1128.00
Loading Dealers...
The Kolpak KFX8-106-CR Kold-Front Walk-In Cooler is a versatile and durable indoor/outdoor remote unit that is designed to deliver cool and steady air. It features a 3/4 horsepower condenser and a 2.5" dial thermometer, ensuring that the contents of the cooler remain at a perfect temperature of 35 degrees Fahrenheit. This floorless unit has a 26 ga. embossed galvalume interior and exterior, along with a standard 34" X 78" door. It measures 102 inches tall, 116 inches wide, and 70 inches deep.
 
 The Kold-Front Walk-In Cooler, with dimensions of 8'-6.25" H, 9'-8" W, and 5'-10" L, is a floorless unit that operates at a medium temperature of +35F. It comes with a pre-charged KPC48MOP and has a power consumption of 5.7 amps at 208-230/60/1. The indoor/outdoor remote unit also includes a KAM16-052-1EC-PR-8 with a power consumption of 0.9 amps at 115/60/1. The interior and exterior of the cooler are made of 26 ga. embossed galvalume, and it comes with 4" vinyl/foam screeds and a 2" dial thermometer.
 
 The cooler is equipped with the ArcticFox Temperature & Air Defrost Control, which combines the functions of a thermostat and defrost timeclock. It is designed for medium temperature applications of 35°F and higher and includes a built-in defrost clock for time-initiated and time-terminated defrost cycles. The controller's single-pole-double-throw relay controls the refrigeration and defrost cycles. For low-temperature applications, the ArcticFox Temperature Control provides a user-friendly thermostat that simplifies operation and eliminates frustration. The ArcticFox also includes a battery-powered clock for proper operation after power is restored.
 
 The ArcticFox Temperature & Air Defrost Control features a thermostat, manual defrost, and a first defrost 2 hours after start-up. It also has visual alarming for high temperature, low temperature, and sensor issues. The controller offers off-time defrost on schedule or custom defrost and includes compressor protection with maximum starts per hour. It also has a service call saver feature and a post-defrost indicator to prevent unnecessary service calls.
 