Kolpak KFX7-0608-CR

Brand
Kolpak
Certifications
NSF
Shipping
Standard Shipping
Nominal Depth
8 Feet
Nominal Width
6 Feet
Series
Kold-Front
Type
Kold-Front
Category
Walk In Cooler,Modular
Compressor Location
Remote
With Floor
Floorless
Usage
Indoor
Voltage
208/230 Volts
Width (in)
70
Height (in)
90
Depth (in)
93
Weight
977.00
Loading Dealers...
The Kolpak KFX7-068-CR Kold-Front Walk-In Cooler is a versatile indoor/outdoor remote unit that does not have a floor. It is equipped with cooling technologies to provide cool and steady air. The cooler has a 3/4 horsepower condenser and a 2" dial thermometer, ensuring that the contents of the cooler remain at a perfect temperature of 35 degrees Fahrenheit. This durable unit has a 26 ga. embossed galvalume interior and exterior and comes with a standard 34" X 78" door. It has dimensions of 90 inches tall, 70 inches wide, and 93 inches deep.
 
 The walk-in cooler, known as Kold-Front, has a height of 7'-6.25", a width of 5'-10", and a length of 7'-9". It is a floorless unit with a 1/2 horsepower medium temperature (+35F) condenser that comes pre-charged with KPC48MOP. The cooler operates at 5.7 amps and requires 208-230/60/1 power. It also includes the KAM16-052-1EC-PR-8, which operates at 0.9 amps and requires 115/60/1 power. This indoor/outdoor remote unit has a 26 ga. embossed galvalume interior and exterior, along with 4" vinyl/foam screeds and a 2" dial thermometer.
 
 The cooler comes with several standard features. It includes the ArcticFox Temperature & Air Defrost Control, which combines the functions of a thermostat and defrost timeclock. This control is designed for medium temperature applications of 35°F and higher and includes a built-in defrost clock for time-initiated and time-terminated defrost cycles. The controller's relay controls the refrigeration and defrost cycles. For low-temperature applications, the ArcticFox Temperature Control provides a simple thermostat for easy operation. It also includes a battery-powered clock for proper operation after power is restored.
 
 The ArcticFox Temperature & Air Defrost Control has additional features such as a manual defrost option, a first defrost 2 hours after start-up, visual alarming for high temperature, low temperature, and sensor issues, and compressor protection with maximum starts per hour. It also includes a service call saver and a post defrost indicator to prevent unnecessary service calls. The control has modbus terminals, a 4-button user