Kolpak KFX7-1206-CR

Brand
Kolpak
Certifications
NSF
Shipping
Standard Shipping
Nominal Depth
6 Feet
Nominal Width
12 Feet
Series
Kold-Front
Type
Kold-Front
Category
Walk In Cooler,Modular
Compressor Location
Remote
With Floor
Floorless
Usage
Indoor
Voltage
208/230 Volts
Width (in)
139
Height (in)
90
Depth (in)
70
Weight
1236.00
Loading Dealers...
The Kolpak KFX7-126-CR Kold-Front Walk-In Cooler is a versatile indoor/outdoor remote unit that does not have a floor. It is equipped with cooling technologies to provide cool and steady air. The cooler has a 1 horsepower condenser and a 2.5" dial thermometer, ensuring that the contents of the cooler remain at a perfect temperature of 35 degrees Fahrenheit. This durable unit features a 26 ga. embossed galvalume interior and exterior, along with a standard 34" X 78" door. It has dimensions of 90 inches tall, 139 inches wide, and 70 inches deep.
 
 The walk-in cooler, known as Kold-Front, has a height of 7'-6.25", a width of 11'-7", and a length of 5'-10". It is a floorless unit with a 3/4 horsepower medium temperature (+35F) condenser that comes pre-charged with KPC68MZOP-2. The unit requires 17.0 amps and operates on 208-230/60/1 voltage. It also includes the KAM26-073-1EC-PR-8, which requires 1.6 amps and operates on 115/60/1 voltage. This indoor/outdoor remote unit has a 26 ga. embossed galvalume interior and exterior, along with 4" vinyl/foam screeds and a 2" dial thermometer.
 
 The cooler comes with several standard features. The ArcticFox Temperature & Air Defrost Control is a combination of a thermostat and defrost timeclock, designed to simplify refrigeration cooler controls. It has a built-in defrost clock that can be used for time-initiated and time-terminated defrost cycles. The controller's relay controls the refrigeration and defrost cycles. The ArcticFox Temperature Control is designed for low-temperature applications and provides an easy-to-understand thermostat. It includes a battery-powered clock for proper operation after power is restored.
 
 The ArcticFox Temperature & Air Defrost Control has additional features such as manual defrost, first defrost 2 hours after start-up, visual alarming for high temperature, low temperature, and sensor issues, off-time defrost on schedule or custom defrost, and compressor protection with maximum starts per hour. It also includes a service call saver and a post defrost indicator to prevent unnecessary service calls.
 
 The hardware of the control includes Mod